INSTEK GPT-9802 CALIBRATION and INSTEK GPT-9802 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GPT-9802 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK GPT-9802   Description / Specification:   Spec Sheet 
INSTEK GPT-9802 5KV AC, 6KV DC Withstanding Voltage Tester

The GW Instek GPT-9802 AC/DC Withstanding Voltage Tester looks to meet a variety of safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety-related requirements for the safety tests of electronic products and components. The GPT-9802 is capable of performing both AC and DC withstanding tests. It is equipped with a simple & clear panel layout, a high resolution dot matrix LCD display, and color LED indicators, allows operators to interpret measurement results easily and quickly. Specifications. AC Output-Voltage Range: 0.100kV to 5.000kV. AC Output-Voltage Resolution: 2V/step. AC Output-Voltage Accuracy: ± (1% of setting +5V) [no load]. AC Maximum Rated Load: 200 VA (5kV/40mA). Output-Voltage Waveform: Sine wave. Output-Voltage Frequency: 50 Hz / 60 Hz selectable. DC Output-Voltage Range: 0.100kV to 6.000kV. DC Output-Voltage Resolution: 2V/step. DC Output-Voltage Accuracy: ± (1% of setting +5V) [no load]. DC Maximum Rated Load: 50W (5kV/10mA). ARC Detect: Yes. RAMP (Ramp-Up Time): 0.1 to 999.9s. TIMER (Test Time): OFF, 0.5s to 999.9s. RS232: Standard. USB (Device): Standard. GPIB: Optional.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GPT-9802. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your INSTEK GPT-9802 CALIBRATION and/or INSTEK GPT-9802 5KV AC, 6KV DC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: